| 注册
首页|期刊导航|传感技术学报|科氏质量流量计振子平衡特性对零点漂移的影响研究

科氏质量流量计振子平衡特性对零点漂移的影响研究

任建新 钱小亮 屈雅琴 刘洪德

传感技术学报2016,Vol.29Issue(9):1311-1316,6.
传感技术学报2016,Vol.29Issue(9):1311-1316,6.DOI:10.3969/j.issn.1004-1699.2016.09.002

科氏质量流量计振子平衡特性对零点漂移的影响研究

Research on the Influence of Balance Characteristics of Oscillator of CMF on Zero Drift

任建新 1钱小亮 1屈雅琴 2刘洪德1

作者信息

  • 1. 西北工业大学自动化学院,西安710129
  • 2. 西安技师学院,西安710077
  • 折叠

摘要

Abstract

The problem of zero drift of Coriolis Mass Flowmeter(CMF)is one of the main constraints to the products in the measurement of accuracy and performance stability. This paper studied the influence of the balance character⁃istics of oscillator to zero,including asymmetry of exciter position,asymmetry of detector position,asymmetry of fixed-pitch plate position,asymmetry of additional mass in the measuring tube and asymmetry of volume of measur⁃ing tube. Besides,this paper also conducted a few simulation analyses and experimental analyses to the factors re⁃sulting in unbalanced of the oscillator of CMF,obtaining the trend of zero value with the intensification of imbalanc⁃es of oscillator,Analyses in this paper can provide theoretical guidance for the design and the performance parame⁃ters to improve of CMF.

关键词

科氏质量流量计/零点漂移/ANSYS Workbench/不平衡

Key words

Coriolis mass flowmeter/zero drift/ANSYS Workbench/unbalance

分类

机械制造

引用本文复制引用

任建新,钱小亮,屈雅琴,刘洪德..科氏质量流量计振子平衡特性对零点漂移的影响研究[J].传感技术学报,2016,29(9):1311-1316,6.

基金项目

国家自然科学基金项目 ()

传感技术学报

OA北大核心CSCDCSTPCD

1004-1699

访问量0
|
下载量0
段落导航相关论文