宁夏电力Issue(4):46-49,72,5.DOI:10.3969/j.issn.1672-3643.2016.04.009
燃煤电站锅炉超低排放技术方案分析研究
Ultra-low emission projects for 600 MW coal-fired generating units
李奎1
作者信息
- 1. 湛江中粤能源有限公司,广东 湛江 524099
- 折叠
摘要
Abstract
In order to meet the new demands of national standards for air pollutant emission concentration of coal-fired generating units, analyzes status quo of air pollutant emission for a 600 MW coal-fired generating unit, puts forward the retrofit scheme of ultra-low pollutant emission such as low NOx combustion + Selective Catalytic Reduction(SCR) denitration + electrostatic- bag precipitator+flue gas desulfurization+wet electrostatic precipitator. The result shows that the emission concentrations of NOx, SO2 and flue gas respectively can control under 50 mg/Nm3, 35 mg/Nm3 and 5 mg/Nm3 after the ultra-low pollutant emission project to put into operation, and it significantly improve the local air quality.关键词
燃煤机组/超低排放/湿式电除尘器Key words
coal-fired power generating unit/ultra-low emission/wet electrostatic precipitator分类
能源科技引用本文复制引用
李奎..燃煤电站锅炉超低排放技术方案分析研究[J].宁夏电力,2016,(4):46-49,72,5.