宁夏电力Issue(4):50-54,5.DOI:10.3969/j.issn.1672-3643.2016.04.010
电站锅炉水冷壁爆管原因分析及对策
Cause analysis and countermeasures on boiler water wall tube explosion in power plant
王新良 1马国伟1
作者信息
- 1. 国电科学技术研究院,宁夏 银川 750011
- 折叠
摘要
Abstract
Aiming at the accident of water wall tube explosion causing by high-temperature corrosion happening in a boiler of power plant, By the methods of macroscopic inspection, metallographic analysis and sediment energy spectrum analysis, finds out the influence factors of high-temperature corrosion of water wall tubes corrosion, brings forward prevention measure. The application result shows that burner improvement and boiler combustion adjustment can control availably the the accident of water wall tube explosion and ensure the safe and steady operation of the boiler.关键词
电站锅炉/水冷壁/高温腐蚀/爆管Key words
power plant boiler/high-temperature corrosion/tube explosion分类
能源科技引用本文复制引用