| 注册
首页|期刊导航|制冷|厦门市商场中央空调系统新风调节与节能分析

厦门市商场中央空调系统新风调节与节能分析

林友芝

制冷2016,Vol.37Issue(3):44-48,5.
制冷2016,Vol.37Issue(3):44-48,5.DOI:10.3696/J.ISSN.1005-9180.2016.03.008

厦门市商场中央空调系统新风调节与节能分析

Fresh Air Regulation and Energy Saving of Central Air-conditioning System for Shopping Malls in Xiamen

林友芝1

作者信息

  • 1. 厦门新洋达工程技术有限公司,厦门361000
  • 折叠

摘要

Abstract

It is found that fresh air is not regulated in central air-conditioning systems for shopping malls based on a survey to several marketplaces in Xiamen. The energy saving potential of fresh air regulation in central air-condi-tioning system is calculated and analyzed based on the field investigation to SM Town Plaza ( the covered area 12600 m2 ) in Xiamen. It is found that the energy cost for the fresh air is 208, 800 Yuan per year. 52, 200 Yuan could be saved if the automatic control device of CO2 concentration is adopted to fresh air system in this case. Moreover, the payback period of technical updates is only 3 months. There is a great potential of energy saving for fresh air regula-tion in central air-conditioning system in shopping centers.

关键词

商场/中央空调/新风/节能

Key words

Shopping center/Central air-conditioning/Fresh air/Energy saving

分类

建筑与水利

引用本文复制引用

林友芝..厦门市商场中央空调系统新风调节与节能分析[J].制冷,2016,37(3):44-48,5.