| 注册
首页|期刊导航|焊管|某海底天然气管线的内腐蚀直接评价

某海底天然气管线的内腐蚀直接评价

李全华 张勇 曲兴刚 白宁

焊管2016,Vol.39Issue(8):58-63,6.
焊管2016,Vol.39Issue(8):58-63,6.DOI:10.19291/j.cnki.1001-3938.2016.08.014

某海底天然气管线的内腐蚀直接评价

Internal Corrosion Direct Assessment Method(ICDA) of Some Submarine Gas Pipeline

李全华 1张勇 1曲兴刚 1白宁2

作者信息

  • 1. 中海石油 中国 有限公司深圳分公司惠州油田作业区,深圳 518067
  • 2. 必维 天津 安全技术有限公司,天津 300061
  • 折叠

摘要

Abstract

In order to assess the internal corrosion condition and remaining service life of submarine gas pipeline from HZ21-1A to FPSO in Huizhou oil field, it adopted ICDA method to assess dry gas pipeline. Pipeline design life is 10 years, at present it has served more than 10 years, moreover it is not suitable for pigging operation. The ICDA method does not need to enter pipeline inside, it can effectively identify pipeline internal corrosion risk. The assessment process includes pre-assessment, indirect testing, detailed testing and post assessment four parts. The assessment results showed that the pipeline meet the requirements to continue to use 5 years.

关键词

海底管道/内腐蚀/ICDA/剩余服役寿命

Key words

submarine pipeline/internal corrosion/internal corrosion direct assessment method(ICDA)/remaining service life

分类

能源科技

引用本文复制引用

李全华,张勇,曲兴刚,白宁..某海底天然气管线的内腐蚀直接评价[J].焊管,2016,39(8):58-63,6.