| 注册
首页|期刊导航|流体机械|电驱动和燃气驱动空气源热泵运行设备的分析

电驱动和燃气驱动空气源热泵运行设备的分析

史丽娜 刘学来 李永安

流体机械2016,Vol.44Issue(8):78-82,5.
流体机械2016,Vol.44Issue(8):78-82,5.DOI:10.3969/j.issn.1005-0329.2016.08.016

电驱动和燃气驱动空气源热泵运行设备的分析

Exergy Analysis of the Operating Equipment of Electricity Engine-driven and Gas Engine-driven Air Source Heat Pump

史丽娜 1刘学来 1李永安1

作者信息

  • 1. 山东建筑大学,山东济南 250101
  • 折叠

摘要

Abstract

The exergy analysis of the gas engine-driven and electricity engine-driven air source heat pump are made. , and the exergy loss, exergy efficiency and thermodynamic perfection degree of each equipment were obtained. The results show that the exergy losses of air source heat pump in the evaporator, compressor, condenser and throttle valve are 0. 372, 2. 722, 1. 219, 0. 322, respectively. When gas engine-driven and electricity engine-driven air source heat pump are all equivalent to primary en-ergy source,the exergy efficiency of the whole system were 22. 52%, 17. 4%,it can be seen that the exergy efficiency of the gas engine-driven air source heat pump is higher than that of the electricity engine-driven air source heat pump , and the gas engine-driven air source heat pump is more economical and energy saving.

关键词

燃气空气源热泵/电驱动空气源热泵/制热/分析

Key words

gas engine-driven air source heat pump/electricity engine-driven air source heat pump/heating/exergy analysis

分类

机械制造

引用本文复制引用

史丽娜,刘学来,李永安..电驱动和燃气驱动空气源热泵运行设备的分析[J].流体机械,2016,44(8):78-82,5.

基金项目

山东省住房和城乡建设部科技计划项目(2014-K1-039) (2014-K1-039)