| 注册
首页|期刊导航|中国内镜杂志|McGrath-5型视频喉镜与 McCoy 喉镜引导困难气道双腔支气管插管的效果比较

McGrath-5型视频喉镜与 McCoy 喉镜引导困难气道双腔支气管插管的效果比较

沈荣荣 杨鑫 李樱青 严峰 王浩杰

中国内镜杂志2016,Vol.22Issue(9):15-19,5.
中国内镜杂志2016,Vol.22Issue(9):15-19,5.DOI:10.3969/j.issn.1007-1989.2016.09.004

McGrath-5型视频喉镜与 McCoy 喉镜引导困难气道双腔支气管插管的效果比较

Comparison of McGrath-5 video-laryngoscope and McCoy laryngoscope guided double-lumen tube intubation in patients with difficult airway

沈荣荣 1杨鑫 1李樱青 1严峰 1王浩杰1

作者信息

  • 1. 浙江省余姚市人民医院 麻醉科,浙江 余姚 315400
  • 折叠

摘要

Abstract

Objective To compare the clinical efficacy of double-lumen tube intubation between McGrath-5 video-laryngoscope and McCoy laryngoscope in patients with difficult airway. Methods Sixty patients who were predicted as difficult double-lumen tube intubation were divided into two groups using random number table method:McGrath-5 video-laryngoscope group (group A, n = 30) and McCoy laryngoscope group (group B, n = 30). All patients were intubated by two laryngoscopes correspondingly after conventional induction. The success rate of the first intubation, intubation time, the ratio of right positioning, the number of SpO2 < 90% within intubation time, the number of pressing the cricoid, the incidence of intubation complications and hemodynamic parameters [The changes in systolic pressure and heart rate and BIS were recorded before induction (T0), glottic exposure upon laryngoscope insertion (T1), immediately after intubation (T2), 3 min (T3) after intubation]. Results The number of pressing the cricoid was smaller in group A than in group B (P < 0.05), whereas the intubation time in group A was significantly higher than that in group B (P < 0.05). The systolic pressure and heart rate at T3 were dramatically reduced compared with those measured at T0 in both groups (P < 0.05). The systolic pressure and heart rate at T1 and T2 in group A were considerably lower in group A than those in group B (P < 0.05). Conclusions Compared with the McCoy laryngoscope, double-lumen tube intubation by McGrath-5 video-laryngoscope can less impact on hemodynamics, less intubation complications, intubation time although prolonged but not for influence the patient's oxygen supply, for difficult airway double-lumen tube intubation provides a good choice.

关键词

McGrath-5 型视频喉镜/McCoy 喉镜/双腔导管/插管法/气管内

Key words

McGrath-5 video-laryngoscope/McCoy laryngoscope/double-lumen tube/intubation/intratracheal

分类

医药卫生

引用本文复制引用

沈荣荣,杨鑫,李樱青,严峰,王浩杰..McGrath-5型视频喉镜与 McCoy 喉镜引导困难气道双腔支气管插管的效果比较[J].中国内镜杂志,2016,22(9):15-19,5.

基金项目

余姚市科技计划项目 ()

中国内镜杂志

OA北大核心CSTPCD

1007-1989

访问量0
|