中国药房2016,Vol.27Issue(27):3861-3863,3864,4.DOI:10.6039/j.issn.1001-0408.2016.27.39
改进HPLC法测定吲哚美辛肠溶片中的有关物质
Determination of Related Substance in Indometacin Enteric-coated Tablet by Improving HPLC
李超1
作者信息
- 1. 重庆市食品药品检验检测研究院,重庆 401121
- 折叠
摘要
Abstract
OBJECTIVE:To improve HPLC for the contents determination of 2-methyl-5-methoxy-indole-3-acetic acid(impuri-ty Ⅰ) and 4-chlorobenzoic (impurity Ⅱ) in Indometacin enteric-coated tablet. METHODS:The column was Phenomenex Phe-nyl-Hexyl with mobile phase of 10 g/L acetic acid solution- acetonitrile(gradient elution)at a flow rate of 1.0 ml/min,the detec-tion wavelength was 254 nm,column temperature was 40℃,injection volume was 20 μl. RESULTS:The linear range was 0.262 2-5.243 0 μg/ml for impurity Ⅰ(r=0.999 8)and 0.252 5-5.050 0 μg/ml for impurity Ⅱ(r=0.999 8);the limits of quanti-tation were 1.12 ng and 0.48 ng,limits of detection were 0.340 ng and 0.146 ng,respectively;RSDs of precision,stability and re-producibility tests were lower than 2%;recoveries were 99.71%-100.52%(RSD=0.28%,n=9) and 100.84%-102.14%(RSD=0.47%,n=9). CONCLUSIONS:The method is accurate and rapid,and can be used for the contents determination of impurity Ⅰand impurityⅡin Indometacin enteric-coated tablet.关键词
高效液相色谱法/吲哚美辛肠溶片/2-甲基-5-甲氧基-1H-吲哚-3-乙酸/4-氯苯甲酸Key words
HPLC/Indometacin enteric-coated tablet/2-methyl-5-methoxy-indole-3-acetic acid/4-chlorobenzoic分类
医药卫生引用本文复制引用
李超..改进HPLC法测定吲哚美辛肠溶片中的有关物质[J].中国药房,2016,27(27):3861-3863,3864,4.