压力容器2016,Vol.33Issue(8):41-48,8.DOI:10.3969/j.issn.1001-4837.2016.08.007
过渡段结构对废热锅炉薄管板应力分布的影响
Influence of Transition Section on Stress Distribution of Thin Tube-sheet for Waste Heat Boiler
张起侨1
作者信息
- 1. 镇海石化工程股份有限公司,浙江 宁波 315042
- 折叠
摘要
Abstract
Using the ANSYS,finite element models of different transition sections of tube-sheets for waste heat boiler were established.The stress field,temperature field and the coupled field of these models were analyzed respectively,thus obtaining the stress distribution of different transition sections.Based on the re-sults of the finite element analysis,the strength evaluation and axial stress of tube checking was made.The analysis results can provide some reference for the design of transition section.关键词
过渡段/废热锅炉/薄管板/应力分布Key words
transition section/waste heat boiler/thin tube-sheet/stress distribution分类
机械制造引用本文复制引用