压力容器2016,Vol.33Issue(8):56-59,69,5.DOI:10.3969/j.issn.1001-4837.2016.08.009
蒸汽发生换热器泄漏原因分析及防止
Analysis and Prevention for Leakage of Steam Heat Exchanger
陈宏伟 1王志刚 2李义民 1张建晓 2姚琪 1石承龙2
作者信息
- 1. 兰州兰石重型装备股份有限公司,甘肃 兰州 730087
- 2. 甘肃省压力容器特种材料焊接重点实验室培育基地,甘肃 兰州 730087
- 折叠
摘要
Abstract
As the study of the steam generator heat exchange device appear leakage reason,by using the methods of SEM,EDS,microscopic analysis of crack pattern,at the same time numerical simulation analy-sis,find out the failure reason,and put the preventive measures.The results show that the key failure rea-sons exist the high concentration solution in gap of tube and tube hole.The high concentration solution re-sults in the crack of the alkaline,high temperature hydrogen sulfide stress corrosion was formed at the crack.The leakage of heat exchanger caused by the corrosion process is intensified.关键词
换热管/缝隙/碱性破裂Key words
heat exchange tube/gap/alkaline break分类
机械制造引用本文复制引用
陈宏伟,王志刚,李义民,张建晓,姚琪,石承龙..蒸汽发生换热器泄漏原因分析及防止[J].压力容器,2016,33(8):56-59,69,5.