中国医疗设备2016,Vol.31Issue(9):109-110,121,3.DOI:10.3969/j.issn.1674-1633.2016.09.030
样本针清洗站改进的研究
Research on Improvements of the Sample Needle Cleaning Station
王超 1赵鹏 1曲艳阳 1姜伟刚1
作者信息
- 1. 安图生物实验仪器 郑州 有限公司,河南 郑州 450000
- 折叠
摘要
Abstract
In this paper, the liquid splashing phenomenon during operation of the sample needle cleaning station was analyzed, improvements of the structure of the station were made based on analysis result, including enlarging volume of the inner and outer wall of the cleaning chamber as well as adding an air permeability device in the drainage pipeline. The experimental results showed that the improved cleaning station alleviated the occurrence of the splashing phenomenon greatly and deserved wider clinical application and promotion.关键词
样本针清洗站/免疫分析仪/溅液/水膜Key words
sample needle cleaning station/immunity analyzer/liquid splashing/water film分类
矿业与冶金引用本文复制引用