In view of the high voltage cable terminal operation failure caused by defects , this paper analyzes the mech-anism of partial discharge , with the combination of AC variable frequency resonant pressure test by using the partial discharge test technology of HFCT ( high frequency current sensor ) , and designs a method to determine cable termi-nation happen failure state detect by monitoring partial discharge pattern of cable termination under different test volt -age.Through the field test , the terminal defect of high voltage cable is found effectively .The problem of high voltage cable project completion acceptance is solved through the application of the test methods , which can be effectively found in cable terminal completion inspection and acceptance imperfections , and have obvious effect on judging high voltage cable terminal failure in advance .It can avoid the failure caused by cable terminal malfunction even terminal head explosion accidents .

关键词

交流变频谐振耐压/局部放电/电缆终端/终端失效

Key words

AC variable frequency resonant pressure/partial discharge/cable terminal/terminal failure