摘要
Abstract
Because of the existence of zero sequence components,the unbalanced compensation of three-phase four-wire system is more complicated than that of three-phase three-wire system. The compensation method of symmetrical component analysis method based on Steinmetz theory in three-phase three-wire system load balancing compensation is considered in the three-phase four-wire system unbalanced load current compensation. Moreover,the compensation mod⁃el of three kinds of constraint equations is given. In the three-phase four-wire system with the three above constraint equations,attempts are made to compensate the zero sequence and negative sequence current for star-connected load, and increase the system power factor to 1. Finally,the Matlab simulation results show that the proposed compensation theory can not only keep the unbalanced current balanced,but also make the power factor of total system be equal to 1 approximately,which proves the correctness of the proposed compensation theory.关键词
对称分量分析法/三相四线制/约束方程/零/负序电流补偿Key words
symmetrical component analysis method/three-phase four-wire system/constraint equation/zero se-quence and negative sequence current compensation分类
信息技术与安全科学引用本文复制引用
王江彬,田铭兴,陈敏,赵远鑫..基于Steinmetz理论的三相四线制不平衡电流补偿[J].电力系统及其自动化学报,2016,28(9):20-26,7.基金项目
国家自然科学基金资助项目(51167009);国家自然科学基金资助项目(51367010);甘肃省科技计划资助项目(1304WC-GA181);兰州市科技计划资助项目 ()