电力系统及其自动化学报2016,Vol.28Issue(9):42-47,6.DOI:10.3969/j.issn.1003-8930.2016.09.007
补偿变压器对基波磁通补偿滤波器的影响
Effects of Compensation Transformer on Fundamental Magnetic Flux Compensation Filter
摘要
Abstract
The design of compensation transformer parameters plays a key role in the filtering effects of the system of ac⁃tive power filter based on fundamental magnetic flux compensation. The influence on system voltage,current amplitude and harmonic caused by compensation transformer′s magnetizing inductance and leakage inductance is studied through theoretical derivation and simulation,and the result shows that the parameters of compensation transformer have com⁃plex effects on the system. However,the design of active power filter can be optimized through simulation and experi⁃ment,which provides a theoretical basis for the engineering design. Finally,a semi physical real-time experiment plat⁃form based on RT-LAB is built to verify the feasibility of fundamental magnetic flux compensation filter and the effects of compensation transformer,parameters on the system.关键词
有源电力滤波器/磁通补偿/基波跟踪/变压器电抗/半实物仿真Key words
active power filter(APF)/magnetic flux compensation/fundamental tracking/transformer reactance/semi physical simulation分类
信息技术与安全科学引用本文复制引用
郑征,张朋..补偿变压器对基波磁通补偿滤波器的影响[J].电力系统及其自动化学报,2016,28(9):42-47,6.基金项目
国家自然科学基金资助项目(61340015);河南省联合基金资助项目 ()