In order to ensure safe operation and reduce structural repair and maintenance costs of per-manently installed suspended access equipment in service,through analyzing safety influence factor of its structure and based on AHP FCEM process,a hierarchical structure model of structural safety evaluation system is built,judgment matrix and fuzzy judgment matrix of security index is obtained,each index weight is calculated,and safety evaluation value of its structure is confirmed.Instance analysis proves that it is feasible that using AHP FCEM process evaluates safety of its structure.This provides theoretical reference for utilization management and maintenance and repair of the equipment.

关键词

擦窗机结构/AHP FCEM/安全性评价

Key words

permanently installed suspended access equipment structure/AHP FCEM/safety evalu-ation

分类

建筑与水利

引用本文复制引用

郑夕健,董建,常晓华..基于AHPFCEM的擦窗机结构安全性评价[J].机械与电子,2016,34(9):11-15,5.