| 注册
首页|期刊导航|工业技术创新|600 MW机组电除尘器三相高效电源改造--以山西鲁晋王曲发电厂为例

600 MW机组电除尘器三相高效电源改造--以山西鲁晋王曲发电厂为例

刘志强

工业技术创新2016,Vol.3Issue(5):888-891,4.
工业技术创新2016,Vol.3Issue(5):888-891,4.DOI:10.14103/j.issn.2095-8412.2016.05.016

600 MW机组电除尘器三相高效电源改造--以山西鲁晋王曲发电厂为例

Innovative Improvement of Three-phase High Efifciency Power Supply in Electrostatic Precipitator for 600 MW Unit--A Case Study on Shanxi Lujin Wangqu Power Plant

刘志强1

作者信息

  • 1. 山西鲁晋王曲发电有限责任公司,山西长治,047500
  • 折叠

摘要

Abstract

Along with the increasing strictness of environmental protection requirements in relevant national standards, innovative improvement of ESP (ElectroStatic Precipitator) for 2×600 MW unit in Shanxi Lujin Wangqu power plant is urgently needed. First, investigations for three techniques including bag-type precipitator, electrostatic-bag compound precipitator, and three-phase high efficiency power supply are carried out. Then, through a series of procedure including improvement scheme design, construction process determination, and technical requirement clarification, construction work is orderly launched. The results of acceptance check show that, efficiency, resistancy, leak out rate and outlet dust concentration of improved ESP all meet the requirement of certified values, and far reach the relevant emission standards. Moreover, the power saving rate is up to 25%~40%, indicating the favorable achievement of both social benefits and economic benefits.

关键词

电除尘器/机组/三相高效电源/技术改造/超低排放

Key words

ElectroStatic Precipitator (ESP)/Unit/Three-phase High Efficiency Power Supply/Innovative Technical Improvement/Ultra-low Emission

分类

信息技术与安全科学

引用本文复制引用

刘志强..600 MW机组电除尘器三相高效电源改造--以山西鲁晋王曲发电厂为例[J].工业技术创新,2016,3(5):888-891,4.

工业技术创新

2095-8412

访问量0
|
下载量0
段落导航相关论文