太原理工大学学报2016,Vol.47Issue(6):728-733,6.DOI:10.16355/j.cnki.issn1007-9432tyut.2016.06.009
设置多喷射器的太阳能喷射制冷系统的性能及优化研究
Performance and Optimization Study of Solar Ejector Refrigeration System with Multiple-Ejectors
摘要
Abstract
Based on the multiple-ejectors of the solar ejector refrigeration system,an operation plan,namely injectors witching,was put forward in which the nozzle is constant,and the size of the spray cooling mixing chamber in the injector is changed.The TRNSYS simulation software was used to simulate the multi-ejector solar ejector refrigeration system and the single ejector re-frigeration system in the typical summer weather and the optimization of the number of ejector in the ejector refrigeration system was set up,The results show that the solar ejector refrigeration system with the multiple-ejectors is superior to the single ejector refrigeration system.The former has a larger hourly refrigerating capacity,the total refrigerating capacity in a day is 15.3% higher than that for the latter;The former has a higher system COP,about 10% higher than that for the latter;The former has a running time one and a half hour longer than the latter.The optimal num-ber of the ejector is three,giving an overall refrigerating capacity about 2.8% larger and the sys-tem COP,about 7% higher than the system with two ejectors.关键词
多喷射器/喷射制冷/TRNSYS/模拟计算Key words
multi-ejector/spray cooling/TRNSYS/simulation分类
能源科技引用本文复制引用
汪汉众,李风雷,田琦,白惠峰..设置多喷射器的太阳能喷射制冷系统的性能及优化研究[J].太原理工大学学报,2016,47(6):728-733,6.基金项目
国际科技合作资助项目:基于喷射-压缩制冷的太阳能光热空调新技术(2013DFA61580) (2013DFA61580)
山西省科技攻关项目资助项目:分级利用太阳能的喷射-压缩复合制冷技术研究(20140313006-6) (20140313006-6)
山西省回国留学人员科研资助项目:多喷式太阳能喷射与蒸发复合制冷技术研究(2016-032) (2016-032)