基于边界元方法的超导核磁共振成像设备高阶轴向匀场线圈优化算法

胡洋 王秋良 李毅 朱旭晨 牛超群

物理学报2016,Vol.65Issue(21):218301-1-218301-8,8.
物理学报2016,Vol.65Issue(21):218301-1-218301-8,8.DOI:10.7498/aps.65.218301

基于边界元方法的超导核磁共振成像设备高阶轴向匀场线圈优化算法

Optimization of magnetic resonance imaging high-order axial shim coils using b oundary element metho d

胡洋 1王秋良 2李毅 1朱旭晨 1牛超群1

作者信息

  • 1. 中国科学院电工研究所,应用超导重点实验室,北京 100190
  • 2. 中国科学院大学,北京 100049
  • 折叠

摘要

Abstract

In this paper, we present a novel nonlinear optimization algorithm for designing a shim coil system, especially a high-order axial shim coil, for a magnetic resonance imaging (MRI) system. In an MRI equipment, in order to eliminate higher-order harmonic components of the magnetic field within the volume of interest (VOI), passive shimming (PS) is adopted in traditional methods. However, such a method is suitable for the global shimming with low accuracy and poor target. Active shimming (AS) makes up for the shortcomings from PS with a set of shim coils which are designed to generate a specific magnetic fields to improve magnetic field homogeneity within the VOI. Because the complexity of wire pattern increases with the order of AS coil increasing, conventional optimization model cannot meet the design requirements for producing the complicated magnetic field. In this paper, we propose a nonlinear optimization method of designing the axial shim coils for an open-style bi-planar MRI system, based on boundary element method. The optimization model is built in light of influence extents of the various parameters on the coil characteristics for different shim coils. In such a new method, the field error between the magnetic field produced by designed shim coil and the desired target value is selected to be an optimal value subjected to some constraints including line spacing and coil radius, which makes it possible to realize the manufacture process. Meanwhile, the more design parameters, which involve not only the stream function values at each node, but also the compensation parameters and/or the number of grid nodes, are regarded as optimized variables to control the magnetic deviation and characteristics of designed coil. By using some designed shim coils for a 0.5 T open style bi-planar superconducting MRI, including Z1, Z2, Z3 and Z4, the efficiency of such a numerical design method is displayed. Especially for high-order shim coils, more optimized parameters are involved to control the magnetic deviation of the coils, thereby providing a more flexible and straightforward method of designing the axial shim coils.

关键词

磁共振成像/匀场线圈/边界元方法/非线性算法

Key words

magnetic resonance imaging/shimming coil/boundary element method/nonlinear optimiza-tion algorithm

引用本文复制引用

胡洋,王秋良,李毅,朱旭晨,牛超群..基于边界元方法的超导核磁共振成像设备高阶轴向匀场线圈优化算法[J].物理学报,2016,65(21):218301-1-218301-8,8.

物理学报

OA北大核心CSCDCSTPCDSCI

1000-3290

访问量0
|
下载量0
段落导航相关论文