电气传动2016,Vol.46Issue(11):76-80,5.DOI:10.19457/j.1001-2095.20161118
不同场景下光伏接入配电网的影响分析
Impact Analysis of Photovoltaic Integrated Into Distribution Network in Different Scenarios
摘要
Abstract
Impact analysis of photovoltaic massively connected to distribution network will be helpful to take measures in advance to improve the power network stability. According to the voltage changes of distribution network under both scenarios contains the photovoltaic single-point and multi-points access to distribution network,Put forward three quantitative indicators,which included voltage difference change rate,static voltage indicator and net loss variation. In view of practical engineering network topologies,the quantitative indicators were calculated to analyze the influence of photovoltaic integrated into the distribution network,and the rationality of photovoltaic access scheme on the demonstration projects was verified. It proves that these quantitative indicators have practical engineering applications value.关键词
光伏/高渗透率/配电网/量化指标Key words
photovoltaic/high permeability/distribution network/quantitative indicators分类
信息技术与安全科学引用本文复制引用
杨苹,许志荣,袁昊哲,彭嘉俊,周少雄..不同场景下光伏接入配电网的影响分析[J].电气传动,2016,46(11):76-80,5.基金项目
国家高技术研究发展计划(2014AA052001) (2014AA052001)
广东省科技计划项目(2012B040303005) (2012B040303005)
南方电网科学研究院科技项目(SEPRI-K143003) (SEPRI-K143003)