广东电力2016,Vol.29Issue(11):120-127,8.DOI:10.3969/j.issn.1007-290X.2016.11.023
考虑不确定因素的关键输电断面分析
Analysis on Key Power Transmission Section Considering Uncertain Factors
靳冰洁 1梁晨2
作者信息
- 1. 广东电网发展研究院有限责任公司,广东 广州 510080
- 2. 中国南方电网超高压输电公司检修试验中心,广东 广州510663
- 折叠
摘要
Abstract
Considering propagation characteristics of load and batch power source fluctuation in network,this paper presents a method for key branch identification based on comprehensive betweenness which is used to fully reflect weak links of the system in particular operational environment or with specific network structure and running model. Then it proposes a power grid partitioning method based on node electrical distance clustering and its modification measures so as to avoid missing im-portant lines. Finally,on the basis of grid partitioning and according to features of power transmission section,it selects key branch leading power transmission section as the key section of system. IEEE 39 node system example is used to verify effec-tiveness of this method. It is able to search for the key power transmission section according to load or batch energy fluctua-tion characteristic and system running mode at any time in actual application,so as to provide basis for adopting security con-trol measures for the system.关键词
综合介数/关键支路/电网分区/输电断面Key words
comprehensive betweenness/key branch/power grid partitioning/power transmission section分类
信息技术与安全科学引用本文复制引用
靳冰洁,梁晨..考虑不确定因素的关键输电断面分析[J].广东电力,2016,29(11):120-127,8.