电测与仪表2016,Vol.53Issue(21):71-75,5.
谐波工况下相位补偿对全波计量影响
The effect on total electric energy metering accuracy of the phase compensation for smart meters under harmonics conditions
周超 1纪峰 1田正其 1祝宇楠 1刘建1
作者信息
- 1. 国网江苏省电力公司电力科学研究院国家电网公司电能计量重点实验室,南京211103
- 折叠
摘要
Abstract
The voltage front-end voltage and the current sampling circuit for smart meters with total electric energy mete-ring models are two independent channels , so there exists extra phase error because of the different attenuation characteris-tics of the two channels .The extra phase error can be effectively reduced by the phase compensation technology under fun-damental power frequency condition .However , the phase compensation based on fundamental power frequency can result in phase over compensation for the high order harmonic component , which will result in the effect on total electric energy me-tering accuracy .This paper will conduct an error analysis from the aspects of total electric energy metering algorithm and the phase compensation technology , and then the model for the total electric energy metering error which caused by phase compensation based on fundamental active power frequency will be built .The quantitative analysis for total electric energy metering error caused by phase compensation will be taken from the simulation by MATLAB .关键词
智能电能表/全波计量/相位补偿/FFTKey words
smart meters/total electric energy metering/phase compensation/FFT分类
信息技术与安全科学引用本文复制引用
周超,纪峰,田正其,祝宇楠,刘建..谐波工况下相位补偿对全波计量影响[J].电测与仪表,2016,53(21):71-75,5.