强激光与粒子束2017,Vol.29Issue(1):016007-1-016007-6,6.DOI:10.11884/HPLPB201729.160212
JMCT程序临界安全基准校验计算与分析
Benchmark experiment and analysis of JMCT on nuclear critical safety
李云龙 1杨海峰 1易璇 1邵增 1霍小东1
作者信息
- 1. 中国核电工程有限公司,北京 100840
- 折叠
摘要
Abstract
JMCT developed by Institute of Applied Physics and Computational Mathematics is a transport code based on Monte Carlo method.A series of benchmark experiments picked up from the international nuclear critical experiment database, were used to validate JMCT.The validation includes common fission nuclides(such as U and Pu),from lower enrichment to high-er enrichment,their thermal neutron groups and fast neutron groups,and common neutron poison and reflector.The results of JMCT were compared with the results of experiments by MCNP and MONK.The correctness of JMCT is preliminarily verified.关键词
JMCT/临界安全/基准实验验证/蒙特卡罗方法Key words
JMCT/nuclear critical safety/benchmark experiment validation/Monte Carlo method分类
能源科技引用本文复制引用