| 注册
首页|期刊导航|中国医疗设备|PET/CT稳定性检测

PET/CT稳定性检测

刘杰 李红磊 刘晓建 续蕊 金超岭 王猛 颜珏

中国医疗设备2016,Vol.31Issue(12):128-130,3.
中国医疗设备2016,Vol.31Issue(12):128-130,3.DOI:10.3969/j.issn.1674-1633.2016.12.035

PET/CT稳定性检测

Stability Tests of PET/CT

刘杰 1李红磊 1刘晓建 1续蕊 1金超岭 1王猛 1颜珏1

作者信息

  • 1. 中日友好医院核医学科,北京 100029
  • 折叠

摘要

Abstract

Objective To strictly implement the stability tests of Positron Emission Tomography Computed Tomography (PET/CT) so as to ensure the secure and stable operation of PET/CT equipment, lower the failure rate, prolong the service span and reduce the maintenance costs of PET/CT equipment. Methods According to the test phantoms and methods in NEMA NU 2-2001, the stability test of PET/CT was explored in this paper from multiple aspects including the detector working state, spatial resolution testing, sensitivity testing, SUV calibration and PET/CT image fusion accuracy testing.Results During the process of PET/CT stability test, the unqualiifed item was timely corrected and the failure rate was reduced so as to guarantee the quality of images.Conclusion The stability test of PET/CT could ensure the image quality and reduce the failure rate.

关键词

PET/CT/探测器/质量控制/稳定性检测

Key words

positron emission tomography/computed tomography/detector/quality control/stability test

分类

医药卫生

引用本文复制引用

刘杰,李红磊,刘晓建,续蕊,金超岭,王猛,颜珏..PET/CT稳定性检测[J].中国医疗设备,2016,31(12):128-130,3.

中国医疗设备

OACSTPCD

1674-1633

访问量0
|
下载量0
段落导航相关论文