制冷学报2016,Vol.37Issue(6):13-19,7.DOI:10.3969/j.issn.0253-4339.2016.06.013
不均匀风速分布下翅片管换热器的优化分析与实验
An Optimized Design and Experimental Research on Finned-tube Evaporator with Nonuniform Air Distribution
王强 1刘燕龙 2刘祖一 3戴希灿4
作者信息
- 1. 山东建筑大学热能工程学院 济南 250101
- 2. 山东电力工程咨询院有限公司 济南 250013
- 3. 中国五洲工程设计集团有限公司 北京 100053
- 4. 德州中傲空调设备有限公司 德州 253000
- 折叠
摘要
Abstract
Airflow distribution has significant impact on the performance of finned⁃tube evaporator. Simulation optimization and experimen⁃tal study were carried out of fin⁃tube heater exchange flow path form with three typical air velocity distributions, when the heat exchanger structure size and inlet air state were under certain conditions. The optimization demonstrates that the capacity is increased by 10. 3%,3%under upper⁃triangular and middle⁃triangular air distribution. The analysis on upper⁃triangular optimized form show that the high air veloci⁃ty profile is the key of improving heat transfer performance, and the COP is increased about 8% with upper⁃triangular air distribution. An experimental rig was built and verification was carried out. The results showed that relative error was in 5%, which indicates that the opti⁃mized and experimental results are basically consistent.关键词
翅片管换热器/不均匀风速/优化分析/实验验证Key words
finned-tube evaporator/nonuniform air distribution/optimization and analysis/experimental verification分类
通用工业技术引用本文复制引用
王强,刘燕龙,刘祖一,戴希灿..不均匀风速分布下翅片管换热器的优化分析与实验[J].制冷学报,2016,37(6):13-19,7.