爆破器材2017,Vol.46Issue(1):34-37,4.DOI:10.3969/j.issn.1001-8352.2017.01.007
电流对灼热桥丝式电雷管点火头发火时间的影响❋
Effect of Current Intensity on the Ignition Time of Hot Bridge-wire Electric Fusehead
高文乐 1周奥博 2朱常胜 1杨磊 2罗衍涛3
作者信息
- 1. 山东科技大学土木工程与建筑学院 山东青岛,266590
- 2. 山东省土木工程防灾减灾重点实验室 山东青岛,266590
- 3. 中国电子科技集团公司第四十一研究所 山东青岛,266590
- 折叠
摘要
Abstract
A rigid detonator fusehead and a LGS-2A millisecond detonator tester were chosen to study the effect of current intensity (1. 0-4. 0 A) on the ignition time of hot bridge-wire electric fusehead. Experimental results show that the ignition time of hot bridge-wire electric fusehead decreases with the increase of current intensity at first, and then tends to be stable. Meanwhile, the ignition time difference for different detonator fuseheads at same current intensity reduces gradu-ally. The stable ignition time of electric fusehead is confirmed as 0. 7 ms.关键词
电流强度/电雷管点火头/发火时间Key words
current intensity/fusehead of electric detonator/ignition time分类
军事科技引用本文复制引用
高文乐,周奥博,朱常胜,杨磊,罗衍涛..电流对灼热桥丝式电雷管点火头发火时间的影响❋[J].爆破器材,2017,46(1):34-37,4.