A new method for evaluating the severity of fault lines is presented to overcome the shortcomings of existing sag methods for exposed area analysis .Based on fault positions method , average voltage magnitude index and the numbers of buses which suffer voltage sag with different magnitudes are used to describe the severity of fault positions . The weights of indexes are determined by using entropy method and the comprehensive severity coefficients of fault po -sitions are then calculated .Average the comprehensive severity coefficient of fault positions which are in a same line to get the comprehensive severity coefficient of each line , and after that , the fault line can be sorted considering the effect of voltage sag at multiple sensitive load buses .Simulation example shows that the proposed method can quantita-tively evaluate the severity of fault positions and lines , and can provide some references for adopting sag mitigation measures.关键词
电压暂降/故障点法/熵权法/严重度系数Key words
voltage sag/fault positions method/entropy method/severity coefficient分类
信息技术与安全科学引用本文复制引用