| 注册
首页|期刊导航|国际医学放射学杂志|能谱CT虚拟平扫替代常规平扫评估甲状腺结节的可行性研究

能谱CT虚拟平扫替代常规平扫评估甲状腺结节的可行性研究

胡镭 罗德红 李琳 林蒙 赵燕风 郭炜 赵心明 周纯武

国际医学放射学杂志2017,Vol.40Issue(1):10-13,4.
国际医学放射学杂志2017,Vol.40Issue(1):10-13,4.DOI:10.19300/j.2017.L4603

能谱CT虚拟平扫替代常规平扫评估甲状腺结节的可行性研究

Feasibility of using virtual non-contrast images derived from spectral CT instead of the true non-contrast images for thyroid nodules evaluation

胡镭 1罗德红 1李琳 1林蒙 1赵燕风 1郭炜 1赵心明 1周纯武1

作者信息

  • 1. 北京协和医学院中国医学科学院肿瘤医院影像诊断科,北京 100021
  • 折叠

摘要

Abstract

Objective The study aimed to determine whether virtual non-contrast (VNC) images derived from spectral CT can replace true non-contrast (TNC) images for thyroid nodules evaluation. Methods Retrospectively analyzed images of 72 patients with thyroid diseases who had undergone traditional plain CT scan and enhanced spectral CT scan in our hospital during Feb.-Oct. 2014. The CT values of different tissues, subjective image quality, objective image quality, diagnostic ability of calcifications, and radiation dose were compared between TNC and VNC images with paired t test and Wilcoxon signed rank test. Results 1. Significant differences were observed in CT values of thyroid nodules and other tissues except fat (P<0.05) between TNC and VNC images. Except of normal thyroid tissues, all the CT value differences were less than 4 HU. There was no significant difference in fat CT values between TNC and VNC images (P>0.05). The noise of VNC images was higher than that of TNC, and the SNR, CNR of VNC images were lower than those of TNC (P<0.05). 2. The median scores of objective image quality of TNC and VNC images both were 4.0, and the score of VNC images was lower than that of TNC, but the difference was not significant (P>0.05). 3.TNC images presented calcification in 24 cases, whereas VNC images in 22 cases. No significant difference was found in calcification number between TNC and VNC images (P>0.05), however the long-axis diameters of the largest calcifications were smaller on VNC images than that on TNC images (P<0.05). 4. The values of dose length product and effective dose of the enhanced spectral CT were much lower than those of TNC plus enhanced CT scan, and the differences were significant(P<0.05). Compared with conventional non-contrast and contrast mode scan, spectrum mode enhanced scan reduced effective dose by 48.76%. Conclusion VNC images could be a potential sub-stitution for TNC images for thyroid nodules evaluation.

关键词

甲状腺结节/体层摄影术,X线计算机/能谱/虚拟平扫

Key words

Thyroid nodules/Tomography, X-ray computed/Spectrum/Virtual non-contrast

分类

医药卫生

引用本文复制引用

胡镭,罗德红,李琳,林蒙,赵燕风,郭炜,赵心明,周纯武..能谱CT虚拟平扫替代常规平扫评估甲状腺结节的可行性研究[J].国际医学放射学杂志,2017,40(1):10-13,4.

国际医学放射学杂志

OA北大核心CSTPCD

1674-1897

访问量0
|
下载量0
段落导航相关论文