With the purpose of highly precise measuring the phase delay distribution of liquid crystal optical phased array,the accuracy and precision of the measuring method of Fourier Quarter-Plate are both analyzed theoretically and evaluated experimentally.Numerical simulations indicate that the error of this method is smaller than 0.3°when we assumed a couple of ordinary parameters on the system.A practical experiment on a standard half wave plate is also accomplished showing that the accuracy is smaller than 0.3°and the repeat precision is also smaller than 0.3°.Simulations and experiments show a good agreement with each other so that a demonstration Fourier Quarter-Plate method can meet the requirement on phase delay measurement better than 0.5°on liquid crystal optical phased array.

关键词

液晶移相/相移检测/傅里叶变换/四分之一波片法

Key words

liquid crystal phase delay/phase delay measurement/Fourier transformation/method of quarter plate