原子能科学技术2017,Vol.51Issue(1):46-51,6.DOI:10.7538/yzk.2017.51.01.0046
反应堆直接安注结构热工影响分析
Analysis of Reactor Direct Safety Injection Tube Structure on Thermal Impact
曹方方 1蒋兴 2翁羽 1王燕燕 1王海军1
作者信息
- 1. 西安交通大学动力工程多相流国家重点实验室,陕西西安 710049
- 2. 上海核工程研究设计院,上海 200233
- 折叠
摘要
Abstract
The experimental model of direct safety injection of the reactor pressure vessel was established and the heat transfer and flow experiments were carried out .The flow mixing , heat transfer coefficient and the corresponding temperature variation of two different injection tube structures ,namely Venturi injection tube and straight tube , in different regions of the pressure vessel were studied in comparative experiment .The flow fields of different safety injection models were verified by visual experiment and the flow resistance characteristics of safety injection under different structures were analyzed .T he results show that there is a big difference in flow resistance of different safety injection tubes .The study results provide an important basis for the reactor pres‐sure vessel safety injection tube design .关键词
压力容器/安注/文丘里/阻力/传热Key words
pressure vessel/safety injection/Venturi/resistance/heat transfer分类
能源科技引用本文复制引用
曹方方,蒋兴,翁羽,王燕燕,王海军..反应堆直接安注结构热工影响分析[J].原子能科学技术,2017,51(1):46-51,6.