数字减影血管造影下血液透析长期导管改良的临床应用

李星 赵向阳 李鹏飞 张凤昌 贺际宏 彭强 郭影丽 李宏梅

中国医学装备2017,Vol.14Issue(1):58-61,4.
中国医学装备2017,Vol.14Issue(1):58-61,4.DOI:10.3969/J.ISSN.1672-8270.2017.01.019

数字减影血管造影下血液透析长期导管改良的临床应用

Clinical application of modified long-term indewelling catheter under DSA in hemodialysis patient

李星 1赵向阳 1李鹏飞 1张凤昌 2贺际宏 3彭强 3郭影丽 1李宏梅1

作者信息

  • 1. 大庆市人民医院肾内科 黑龙江 大庆 163310
  • 2. 大庆市人民医院超声科 黑龙江 大庆 163310
  • 3. 大庆市人民医院介入科 黑龙江 大庆 163310
  • 折叠

摘要

Abstract

Objective:To investigate the modified method and the effect of establishing long-term catheter indwelling under DSA in hemodialysis.Methods: 68 patients were selected to treated with long-term catheter of polyester set in DSA, which were in the end stage of renal failure with long-term hemodialysis therapy. In these patients, some of them couldn't receive intra-arteriovenous fistula surgery because their arteriovenous were poor quality and others had treated with long-term catheter dwelling because their intra-arteriovenous fistula couldn't keep hemodialysis. 68 patients were divided into traditional surgery group and improved surgical group according to different operation methods. 10 cases of traditional surgery group were done with traditional long-term catheterization of internal jugular vein, and 58 cases of improved surgical group with improved long-term catheterization of internal jugular vein catheter. The traditional long-term catheterization was combined Seldinger technology with avulsion of the catheter sheath. The improved method was done by the guide wire. To observe series of operation result, such as the difficulty level, bleeding during and after operation.Results: In 10 traditional catheterization cases, 4 cases couldn't be placed catheter of polyester set under the skin at once because of the contraction of the subcutaneous tissue. 7 cases occurred bleeding above 10ml during operation. In 6 cases, there was an obvious puncture point or tunnel outlet bleeding in 48 hours. Improved intubation patients all disposable catheter placement in the desired position at once. In only 2 cases, there was a significant puncture point or bleeding in the tunnel.Conclusion: With the help of DSA guidance, long-term catheterization can be performed accurately, safely and easily. By the improved method, the amount of bleeding is smaller, and the safety effect is better.

关键词

数字减影血管造影技术/双腔带Cuff长期留置导管/血液透析/改良

Key words

Digital substract angiography/Long-term indwelling catheter in double cavity with Cuff/Hemodialysis/Improvement

分类

医药卫生

引用本文复制引用

李星,赵向阳,李鹏飞,张凤昌,贺际宏,彭强,郭影丽,李宏梅..数字减影血管造影下血液透析长期导管改良的临床应用[J].中国医学装备,2017,14(1):58-61,4.