| 注册
首页|期刊导航|现代妇产科进展|两种HPV检测方法在宫颈癌筛查中准确性比较的Meta分析

两种HPV检测方法在宫颈癌筛查中准确性比较的Meta分析

吕江涛 周德平 杨君 龙馨 但阳

现代妇产科进展2017,Vol.26Issue(2):91-95,5.
现代妇产科进展2017,Vol.26Issue(2):91-95,5.DOI:10.13283/j.cnki.xdfckjz.2017.02.003

两种HPV检测方法在宫颈癌筛查中准确性比较的Meta分析

Diagnostic accuracy of HPV E6/E7 mRNA and DNA hybrid capture 2 for cervical canc-er screening:a meta-analysis

吕江涛 1周德平 1杨君 1龙馨 1但阳1

作者信息

  • 1. 重庆市妇幼保健院宫颈病特色专科,重庆 400013
  • 折叠

摘要

Abstract

Objective:To evaluate and compare the diagnostic value of HPV E6/E7 mRNA (Aptima) and HPV DNA hybrid capture (HC2) for cervical cancer by meta-analysis. Methods:All literatures for cervical cancer screening with Aptima and HC2 were collected. Sensitivity and specificity were pooled using random-effect or fixed-effect model. Summary re-ceiver operating characteristic curve analysis was used to evaluate the diagnostic value of Apti-ma and HC2. Results:Thirteen studies were included in the meta-analysis,with 31523 cases in routine screening and 13982 cases in referral population. The pooled sensitivity of Aptima and HC2 for detecting ≥CIN2 in routine screening were 0 . 95 ( 95%CI:0 . 91 ~0 . 98 ) and 0 . 95 (95%CI:0. 90 ~0. 97),and the pooled specificity were 0. 90(95%CI:0. 90 ~0. 98) and 0. 85(95%CI:0. 84~0. 86),respectively. The Q*value of Aptima and HC2 were 0. 9672 and 0. 8888 in routine screening,and 0. 7708 and 0. 8070 for referral population,respectively. There was no statistical significance between the two. Conclusion:Compared with HC2,Aptima has comparable sensitivity and similar discrimination ability,but have higher specificity.

关键词

人乳头瘤病毒/宫颈癌筛查/meta分析

Key words

Human papillomavirus/Cervical cancer screening/Meta-analysis

分类

医药卫生

引用本文复制引用

吕江涛,周德平,杨君,龙馨,但阳..两种HPV检测方法在宫颈癌筛查中准确性比较的Meta分析[J].现代妇产科进展,2017,26(2):91-95,5.

现代妇产科进展

OA北大核心CSCDCSTPCD

1004-7379

访问量2
|
下载量0
段落导航相关论文