摘要

Abstract

Because of the low sampling rate in digital substation sampled values messages,the non-integer-period sampling phenomenon is more obvious compared with conventional substation.Spectrum leakage and picket-fence effect are more serious.In this paper,Fourier transform error is analyzed from two aspects of amplitude error and phase error under different sampling points and grid frequency by precise mathematical derivation.The method of selecting the optimal initial phase angle is found.The compensation algorithm to reduce this error is given.It can significantly improve the accuracy of analysis.

关键词

数字化变电站/采样值报文/非整周期采样/傅里叶变换/最优起始相位角

Key words

digital substation/sampled values messages/non-integer-period sampling/Fourier transform/optimal initial phase