摘要
Abstract
When power electronic transformer(PET)is connected to distribution network,it may cause stability prob-lems such as harmonic resonance. Accordingly,an analysis method of resonance stability and a principle of input imped-ance optimization are proposed for the PET connected to active distribution network. First,the topological structure and operation characteristics of PET connected to 10kV distribution network are analyzed;then,a stability assessment method is proposed for the PET connected to active distribution network based on the impedance ratio criterion;further-more,according to the frequency response characteristic curve of the PET filter impedance,the filter parameters of ca-pacitance and impedance in grid side are optimized to improve the dynamic stability of the PET connected to active dis-tribution network;finally,a simulation model of a 10kV active distribution network connected with three PETs is estab-lished considering the factors of electrical distance and filter impedance,etc. The effectiveness of the proposed stability assessment and impedance optimization method is verified by system simulation test.关键词
配电网/电力电子变压器/稳定性/阻抗比判据Key words
power distribution network/power electronic transformer(PET)/stability/impedance ratio criterion分类
信息技术与安全科学引用本文复制引用
葛云霞,李勇,韩继业,段义隆,曹一家,唐伟斌..PET接入10kV有源配电网的谐振稳定评估及输入阻抗优化[J].电力系统及其自动化学报,2017,29(2):1-6,55,7.基金项目
国家自然科学基金资助项目(61233008,51520105011) (61233008,51520105011)
科技部国际合作项目(2015DFR70850) (2015DFR70850)
湖南省科技计划资助项目(2015GK1002,2015RS4022) (2015GK1002,2015RS4022)
国家电网公司科学技术资助项目(面向智慧城市的智能电网园区能源优化管理关键技术研究与应用) (面向智慧城市的智能电网园区能源优化管理关键技术研究与应用)