| 注册
首页|期刊导航|电网技术|双馈风电场感应发电机效应的安全风险评估方法

双馈风电场感应发电机效应的安全风险评估方法

陈武晖 王丹辉 宿端鹏 董鹏 谭伦农 于焰均

电网技术2017,Vol.41Issue(3):854-862,9.
电网技术2017,Vol.41Issue(3):854-862,9.DOI:10.13335/j.1000-3673.pst.2016.1384

双馈风电场感应发电机效应的安全风险评估方法

Risk-Based Security Assessment Method of IGE Caused by Doubly-Fed Wind Farms

陈武晖 1王丹辉 1宿端鹏 1董鹏 2谭伦农 1于焰均1

作者信息

  • 1. 江苏大学 电气信息工程学院,江苏省 镇江市 212013
  • 2. 中国电力科学研究院,北京市 海淀区 100192
  • 折叠

摘要

Abstract

Security assessment ofsubsynchronousresonance (SSR) caused by wind power generation mainlyadopts deterministicassessment methods without considering wind speeduncertainty.Results fromdeterministicsecurity assessmentmaybe too optimistic ortooconservative to reflect securitypostures.In order to analyze impact ofwind speed uncertaintyon SSRin wind farms, this paper definesarisk matrix andarisk index, and develops a SSR-orientedsecurity risk assessment method using probabilistic collocation method. The proposed method is used to assess SSRsecurity riskof a wind farmwithimpactof windspeeduncertaintyon SSRtaken into consideration.Results show that SSRsecurityriskof the system with lower level of series compensation decreases with increaseof average wind speeds, whileSSRsecurityriskof the system withhigherlevel of series compensation risesup with increaseof average wind speeds. Under the same wind speed distribution,with increaseofseries compensation level, SSR securityrisk of the systemincreasesat first and then decreases.

关键词

次同步谐振/感应发电机效应/次同步控制失稳

Key words

KEY WORDS:subsynchronous resonance/induction generator effect(IGE)/subsynchronous control instability

分类

信息技术与安全科学

引用本文复制引用

陈武晖,王丹辉,宿端鹏,董鹏,谭伦农,于焰均..双馈风电场感应发电机效应的安全风险评估方法[J].电网技术,2017,41(3):854-862,9.

基金项目

国家自然科学基金项目(51277089,51407168). Project Supported by National Natural Science Foundation of China (NSFC) (51277089, 51407168). (51277089,51407168)

电网技术

OA北大核心CSCDCSTPCD

1000-3673

访问量0
|
下载量0
段落导航相关论文