| 注册
首页|期刊导航|塑料科技|ICP-OES与ICP-MS测定塑格悬浮式运动地板中的Pb、Cd、Cr和Hg

ICP-OES与ICP-MS测定塑格悬浮式运动地板中的Pb、Cd、Cr和Hg

魏远芳 李奇映 余巧玲 钟俊芳 王万卷

塑料科技2017,Vol.45Issue(3):85-89,5.
塑料科技2017,Vol.45Issue(3):85-89,5.DOI:10.15925/j.cnki.issn1005-3360.2017.03.013

ICP-OES与ICP-MS测定塑格悬浮式运动地板中的Pb、Cd、Cr和Hg

Determination of Lead, Cadmium, Chromium and Mercury in Plastic Suspension Assembly Athlatic Floor by ICP-OES and ICP-MS

魏远芳 1李奇映 2余巧玲 1钟俊芳 2王万卷1

作者信息

  • 1. 国家高分子工程材料及制品质量监督检验中心(广东),广东广州510110
  • 2. 广州质量监督检测研究院,广东 广州 510110
  • 折叠

摘要

Abstract

By studying digestion effect with the different digestion system of plastic suspension assembly athletic floor,the microwave digestion system was established with the HNO3-H2O2-HF,and methods for determination of four heavy metals including lead,cadmium,chromium,mercury in plastic suspension assembly athletic floor by Inductively Coupled plasma optical emission spectrometry(ICP-OES) and inductively coupled plasma mass spectrometry(ICP-MS) have been developed.The linear correlation coefficients of ICP-OES and ICP-MS were both more than 0.999.For ICP-MS,recovery rates were between 82.0% and 111.5% and the relative standard diviations were from 0.1% to 11.1%.By ICP-MS,the recoverises were 97.1%~116.5%,and the relative standard diviations were 0.2%~9.2%.The results indicate that two methods are rapid,simple,and have good accuracy and precision and suitable for determination of the four heavy metals in plastic suspension assembly athletic floor.ICP-MS has lower detection limit and has important applications in trace and ultra trace analysis.However,the instrument is expensive and low popularizing rate.ICP-OES has higher popularizing rate in local laboratory.

关键词

塑格悬浮式运动地板/微波消解/ICP-MS/ICP-OES/重金属

Key words

Plastic suspension assembly athletic floor/Microwave digestion/Inductively coupled plasma mass spectrometry (ICP-MS)/Inductively coupled plasma optical emission spectrometry (ICP-OES)/Heavy metal

分类

化学化工

引用本文复制引用

魏远芳,李奇映,余巧玲,钟俊芳,王万卷..ICP-OES与ICP-MS测定塑格悬浮式运动地板中的Pb、Cd、Cr和Hg[J].塑料科技,2017,45(3):85-89,5.

基金项目

广州市质量技术监督局科技项目(2014KJ40) (2014KJ40)