| 注册
首页|期刊导航|物理学报|6611—6618cm−1之间氨气光谱线强的测量

6611—6618cm−1之间氨气光谱线强的测量

聂伟 阚瑞峰 许振宇 杨晨光 陈兵 夏晖晖 魏敏 陈祥 姚路

物理学报2017,Vol.66Issue(5):131-139,9.
物理学报2017,Vol.66Issue(5):131-139,9.DOI:10.7498/aps.66.054207

6611—6618cm−1之间氨气光谱线强的测量

Measurements of line strengths for some lines of ammonia in 6611–6618 cm?1

聂伟 1阚瑞峰 2许振宇 1杨晨光 1陈兵 1夏晖晖 1魏敏 1陈祥 2姚路1

作者信息

  • 1. 中国科学院合肥物质科学研究院,安徽光学精密机械研究所,环境光学与技术重点实验室,合肥 230031
  • 2. 中国科学技术大学,合肥 230026
  • 折叠

摘要

Abstract

The target gas molecular absorption spectrum parameters especially line strengths are very important for mea-suring temperature and concentration with tunable diode laser absorption spectroscopy (TDLAS) technique. Usually, researchers use line strengths which come from spectrum database, like HITRAN and GEISA and HITEMP spectra database, but those database include values from the theoretical computation, as is well known, there is a big error between the theoretical value and the actual value. In order to modify the line strengths of the database, 20 ammonia spectrum absorption lines in a wavenumber range between 6611 and 6618 cm?1 are measured at different pressures by using direct tunable diode laser absorption spectroscopy (dTDLAS) technique. The measurement procedure is repeated at least 10 times at each pressure, and then average value is calculated. Voigt fitting is used to obtain all line integral area, and then the line integral area is obtained by linear fitting. The slope of the fitting straight line equals line strength. Uncertainty analysis is given for the measurements. The measured linestrength is a function of integrated area, tem-perature, pressure, species mole fraction and effective path length. So, the calculated linestrength uncertainties based on those parameters uncertainties, and the uncertainties of pressure, species mole fraction and effective path length are similar for all transitions with ?P =0.25%, ?χ =0.2%, and ?L =0.4%. The uncertainties of the integrated area and temperature are related to different lines, and their values come from the actual measurement. In the end, uncertainty propagation formula is used to calculate linestrength uncetainty. Uncertainties of our measured line strengths are in a 0.81%–3.33%range. Our measured line strength values are different from line strengths in the HITRAN 2012 database, and the deviations are in 0.51%–17.28%range.

关键词

氨气/可调谐半导体激光吸收光谱技术/线强/不确定度

Key words

ammonia/tunable diode laser absorption spectroscopy/line strengths/uncertainties

引用本文复制引用

聂伟,阚瑞峰,许振宇,杨晨光,陈兵,夏晖晖,魏敏,陈祥,姚路..6611—6618cm−1之间氨气光谱线强的测量[J].物理学报,2017,66(5):131-139,9.

基金项目

国家重大科学仪器设备开发专项 (批准号:2014YQ060537)资助的课题.Project supported by the National Key Scientific Instrument and Equipment Development Project of China (Grant No. 2014YQ060537). (批准号:2014YQ060537)

物理学报

OA北大核心CSCDCSTPCDSCI

1000-3290

访问量5
|
下载量0