| 注册
首页|期刊导航|中国组织工程研究|Acu-Loc(R)2桡骨远端掌侧骨板系统修复桡骨远端C型骨折

Acu-Loc(R)2桡骨远端掌侧骨板系统修复桡骨远端C型骨折

陈群群 乔荣勤 段瑞奇 胡年宏 李钊 邵敏

中国组织工程研究2017,Vol.21Issue(7):1025-1030,6.
中国组织工程研究2017,Vol.21Issue(7):1025-1030,6.DOI:10.3969/j.issn.2095-4344.2017.07.008

Acu-Loc(R)2桡骨远端掌侧骨板系统修复桡骨远端C型骨折

Acu-Loc(R)2 volar distal radius bone plate system for repairing type C fracture of distal radius

陈群群 1乔荣勤 1段瑞奇 1胡年宏 1李钊 1邵敏1

作者信息

  • 1. 广州中医药大学附属骨伤科医院,广东省广州市 510240
  • 折叠

摘要

Abstract

BACKGROUND:Distal radius C fractures belong to multiple fractures in the joint. Its treatment should recover various angles and joint surface continuity outside the joint. The recovery of palmar tilt angle, radial inclination angle and radial height is also very important for treating distal radius. OBJECTIVE:To study the changes in palmar tilt angle, radial inclination angle and radial height after type C fractures of the distal radius repaired with Acu-Loc(R)2 VDR bone plate system. METHODS:From May 2015 to March 2016, 11 cases of type C distal radial fractures were treated with Acu-Loc(R)2 VDR bone plate system. Preoperatively, the palmar tilt angle was-31° to-4° (-12.45° on average), and the radial inclination angle was 6° to 18° (11.18° on average), and the radial height was 1.92 mm to 8.68 mm (5.28 mm on average). X-ray films were observed at postoperative 4, 8 and 12 weeks and half a year in all patients. Palmar tilt angle, radial inclination angle and radial height were measured and observed using anteroposterior and lateral X-ray films during final follow-up. Wrist function was assessed with Gartland-Werley score. RESULTS AND CONCLUSION:(1) 11 patients were followed and the postoperative follow-up ranged from 7 months to 15 months. X-ray films showed that the union of fractures was achieved in 6-8 weeks (6.5 weeks on average). No infection or internal fixation failure occurred. The articular facets were smooth in 10 patients and a little poor was found in 1 case (<2 mm). (2) After operation, the palmar tilt angle was 8° to 15° (11.55° on average) (P<0.05);the radial inclination angle was 22° to 27° (23.18° on average) (P<0.05);the radial height was 8.01 mm to 13 mm (11.03 mm on average) (P<0.05). (3) The results were excellent in 8 cases, good in 2 cases, and poor in 1 cases according to Gartland-Werley wrist function assessment;the excellent and good rate was 91%. (4) Acu-Loc(R)2 VDR bone plate fixation can provide reliable fixation and effective support for type C distal radius fractures, which can recover the palmar tilt angle, the radial inclination angle and the radial height, so the Acu-Loc(R)2 VDR bone plate is an ideal method to treat type C fractures of the distal radius.

关键词

骨科植入物/骨植入物/桡骨远端C型骨折/内固定/Acu-Loc(R)2VDR

分类

医药卫生

引用本文复制引用

陈群群,乔荣勤,段瑞奇,胡年宏,李钊,邵敏..Acu-Loc(R)2桡骨远端掌侧骨板系统修复桡骨远端C型骨折[J].中国组织工程研究,2017,21(7):1025-1030,6.

基金项目

广东省中医药局科研项目(20161122) the Scientific Research Program of Guangdong Provincial Bureau of Traditional Chinese Medicine, No. 20161122 (20161122)