| 注册
首页|期刊导航|中国中医药信息杂志|基于瞬时波强技术构建濡脉脉象图特征分析

基于瞬时波强技术构建濡脉脉象图特征分析

郑星宇 郭思薇 魏世超 骆杰伟 曹双双 林宁 叶振盛 郭苗苗 孟晓嵘

中国中医药信息杂志2017,Vol.24Issue(4):19-23,5.
中国中医药信息杂志2017,Vol.24Issue(4):19-23,5.DOI:10.3969/j.issn.1005-5304.2017.04.006

基于瞬时波强技术构建濡脉脉象图特征分析

Analysis on Construction of Moisten Pulse Images Based on Wave Intensity Technology

郑星宇 1郭思薇 2魏世超 3骆杰伟 2曹双双 1林宁 2叶振盛 3郭苗苗 2孟晓嵘2

作者信息

  • 1. 福建医科大学省立临床医学院,福建福州 350001
  • 2. 福建省立医院,福建福州 350001
  • 3. 福建中医药大学,福建福州 350108
  • 折叠

摘要

Abstract

Objective To enrich the objective study of TCM pulse through constructing preliminary moisten pulse images by wave intensity (WI) technology.Methods The study subjects were divided into moisten pulse group (28 cases) and normal pulse group (30 cases). The cunkou pulse conditions were examined by color Doppler ultrasonic diagnostic equipment (ALOKA Prosoundα 10) and wave intensity (WI) pulse images and data were recorded and collected. WI pulse image of moisten pulse and normal pulse were constructed and compared by three-dimensional levels of pressure wave (P wave), blood-flow-velocity wave (U wave), WI wave [the product of blood pressure changes (dP/dt) and blood-flow-velocity changes (dU/dt)], and time. ResultsThe U wave of cunkou moisten pulse based on WI was characterized by a more flat curve, a smaller amplitude and a wider wave than the wave of normal pulse. The slopes of both ascending and descending branches of U wave were lower than those of normal pulse. Dicrotic wavefront (tide wave, h3) of P wave was closed to the main wave (h1) or arrives earlier to make it integrates with the main peak into a large round blunt flat top. Even more h3 was higher than h1, which come into being a notch in the declined branch. Comparing with cunkou pulse, forward compression wave of moisten pulse (W1) was reduced,and its forward expansion wave (W2) increased, and W2 wave appeared at the far from the W1 wave. WI wave displayed an angle-like-shape and its descending branch concave was upward. W1, pre-ejection period (R-1st), ejection time (1st-2nd) and augmentation index (AI) decreased compared with normal pulse (P<0.05), while W2 and pulse wave velocity by WI value deduced (PWV-WI) of moisten pulse increased (P<0.05). After adjusting confounding factors, the mean difference of W1, W2, R-1st, 1st-2nd, AI, and PWV-WI between two groups was still significance (P<0.05).Conclusion Moisten pulse WI pulse image constructed from three-dimensional levels of P wave, U wave, and WI wave can more accurately reflect characteristics of moisten pulse wave and guide TCM clinical pulse diagnosis better.

关键词

瞬时波强技术/濡脉/平和脉/脉象图

Key words

wave intensity/moisten pulse/normal pulse/pulse images

分类

医药卫生

引用本文复制引用

郑星宇,郭思薇,魏世超,骆杰伟,曹双双,林宁,叶振盛,郭苗苗,孟晓嵘..基于瞬时波强技术构建濡脉脉象图特征分析[J].中国中医药信息杂志,2017,24(4):19-23,5.

基金项目

福建省科技计划重点项目(2014Y0007) (2014Y0007)

福建省中医药科研项目(wzrk201314) (wzrk201314)

中国中医药信息杂志

OACSCDCSTPCD

1005-5304

访问量7
|
下载量0
段落导航相关论文