长春工程学院学报(自然科学版)2016,Vol.17Issue(4):36-40,5.DOI:10.3969/j.issn.1009-8984.2016.04.010
微压内循环多生物相反应器中试研究的启动与运行
The Start-up and Operation of the Micro-pressureInner Loop Multi-biological Phase Reactor Pilot Study
摘要
Abstract
This paper introduces the structure and principle of micro-pressure inner loop multi-biological phase reactor developed on the basis of the traditional activated sludge method,and makes pilot study of 66 days continuous commissioning and operation by taking city wastewater of a new development district as the experimental water.The results show that the reactor has better resistance to impact load;after the commissioning operation for 23 days,the reactor enters the stable running state.The average removal efficiencies of COD、SS、NH3-N、TP reached 82.06%,77.34%,97.71% and 88.09% respectively.The effluent quality of total nitrogen meets the "Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant" (GB 18918-2002).关键词
微压反应器/中试研究/城市污水/调试运行Key words
the micro-pressure reactor/pilot study/city wastewater/commissioning and operation分类
资源环境引用本文复制引用
熊磊,边德军,吴忌,艾胜书,钟玲,刘伟华..微压内循环多生物相反应器中试研究的启动与运行[J].长春工程学院学报(自然科学版),2016,17(4):36-40,5.基金项目