| 注册
首页|期刊导航|电力科技与环保|串联吸收塔分级控制对脱硫系统性能影响的优化研究

串联吸收塔分级控制对脱硫系统性能影响的优化研究

车凯 郁金星 韩忠阁

电力科技与环保2017,Vol.33Issue(2):44-46,3.
电力科技与环保2017,Vol.33Issue(2):44-46,3.

串联吸收塔分级控制对脱硫系统性能影响的优化研究

Optimization research on influence of series-connected absorption tower hierarchical control on wet desulfurization system

车凯 1郁金星 1韩忠阁1

作者信息

  • 1. 国网河北省电力公司电力科学研究院,河北 石家庄 050021
  • 折叠

摘要

Abstract

The influence of Series-connected absorption tower slurry pH value,tower slurry level and hierarchical control to desulfurization efficiency, SO2 emission characteristics and energy consumption were researched for different inlet SO2 concentration in full load condition on series-connected absorption tower of limestone-gypsum wet flue gas desulfurization system which transformed completion recently.It is concluded that the best way to system operation control mode under different inlet SO2 concentration range in full load condition, which provided a basis and reference to the actual optimal operation control on series-connected absorption tower.

关键词

湿法烟气脱硫系统/串联吸收塔/分级控制/优化

Key words

wet flue gas desulfurization system/series-connected absorption tower/hierarchical control/optimization research

分类

资源环境

引用本文复制引用

车凯,郁金星,韩忠阁..串联吸收塔分级控制对脱硫系统性能影响的优化研究[J].电力科技与环保,2017,33(2):44-46,3.