| 注册
首页|期刊导航|广东电力|600MW机组“超低排放”下新增湿式静电除尘器性能试验的关键问题

600MW机组“超低排放”下新增湿式静电除尘器性能试验的关键问题

李德波 曾庭华 廖永进 周杰联 李方勇 冯永新

广东电力2017,Vol.30Issue(1):1-6,6.
广东电力2017,Vol.30Issue(1):1-6,6.DOI:10.3969/j.issn.1007-290X.2017.01.001

600MW机组“超低排放”下新增湿式静电除尘器性能试验的关键问题

Key Problems in Performance Experiment on New Wet Electrostatic Precipitator Under Ultra-low Emission of 600 MW Unit

李德波 1曾庭华 1廖永进 1周杰联 1李方勇 1冯永新1

作者信息

  • 1. 广东电网有限责任公司电力科学研究院,广东广州510080
  • 折叠

摘要

Abstract

This paper studies field performance experiment on major operational performance index of the new wet electrostatic precipitator (WESP) of 600 MW unit in one thermal power plant,which includes index of dust emission mass concentration and removal efficiency,PM10,and PM2.5 emission mass concentration and removal efficiency,liquid drop content,SO3 mass concentration,Hg concentration,body resistance,flue resistancc,system power consumption,and so on.Experimental results indicate that all performance index of WFSP can meet requirements for design and average dust emission mass concentration at the exit of WESP is 3.43 mg/m3 under the standard state which can satisfy requirement for environment protection.It proves feasibility of the method for field performance experiment on WESP.

关键词

湿式电除尘器/性能试验/超低排放/粉尘浓度/粉尘脱除率

Key words

wet electrostatic precipitator/performance experiment/ultra-low emission/dust concentration/dust removal efficiency

分类

能源科技

引用本文复制引用

李德波,曾庭华,廖永进,周杰联,李方勇,冯永新..600MW机组“超低排放”下新增湿式静电除尘器性能试验的关键问题[J].广东电力,2017,30(1):1-6,6.

基金项目

国家自然科学基金重点资助项目(51376161) (51376161)

广东电力

OACSTPCD

1007-290X

访问量0
|
下载量0
段落导航相关论文