| 注册
首页|期刊导航|临床与病理杂志|TaqMan探针法与尿素呼气试验法检测胃镜活检标本幽门螺旋杆菌的比较

TaqMan探针法与尿素呼气试验法检测胃镜活检标本幽门螺旋杆菌的比较

沈和德 褚明亮 易韦 杨文秀

临床与病理杂志2017,Vol.37Issue(3):473-477,5.
临床与病理杂志2017,Vol.37Issue(3):473-477,5.DOI:10.3978/j.issn.2095-6959.2017.03.005

TaqMan探针法与尿素呼气试验法检测胃镜活检标本幽门螺旋杆菌的比较

Comparison of TaqMan PCR method and Carbon-14-Urea breath test in the diagnosis of Helicobacter pylorus

沈和德 1褚明亮 1易韦 1杨文秀2

作者信息

  • 1. 贵州医科大学附属人民医院病理科,贵阳 550002
  • 2. 贵州医科大学 病理学教研室,贵阳 550004
  • 折叠

摘要

Abstract

Objective: To investigate and compare TaqMan PCR method and Carbon-14-Urea breath test on Helicobacter pylori (Hp) detection. Methods: TaqMan PCR method was used in 70 cases of clinical samples, and the results were analyzed. Results: There was no difference in the positive rate of Hp in TaqMan PCR method and Carbon-14-Urea breath test, and there was a good correlation between the two methods, but the positive rate was higher in Carbon-14-Urea breath test. Further study showed that the positive intensity of Hp can be divided into 3 types by TaqMan PCR method, and there was a good correlation between positive intensity and pathological degree of inflammation. Conclusion: TaqMan PCR method can be used as a useful molecular biological method for clinical diagnosis of Hp.

关键词

幽门螺旋杆菌/TaqMan探针法/尿素呼气试验法

Key words

Helicobacter pylori/TaqMan PCR method/Carbon-14-Urea breath test

引用本文复制引用

沈和德,褚明亮,易韦,杨文秀..TaqMan探针法与尿素呼气试验法检测胃镜活检标本幽门螺旋杆菌的比较[J].临床与病理杂志,2017,37(3):473-477,5.

基金项目

国家自然科学基金(81560088).This work was supported by National Natural Science Foundation of China (81560088). (81560088)