核化学与放射化学2017,Vol.39Issue(1):69-71,3.DOI:10.7538/hhx.2017.39.01.0069
不锈钢放射性模拟样片在空气中的激光去污技术
Laser Decontamination Research on Radioactive Simulated Specimens in Air
马梅花 1高智星 2汤秀章 2郑佐西 1朱欣研 1张怡 1刘雨昕1
作者信息
- 1. 中国原子能科学研究院放射化学研究所,北京102413
- 2. 中国原子能科学研究院核技术应用研究所,北京102413
- 折叠
摘要
Abstract
The study on the laser decontamination parameters was carried on with the simulated radioactive specimens made by LLRW and using APEX laser.The efficiency of different laser parameters such as laser intensity,laser frequency,laser angle and laser scanning speed were investigated on the decontamination factor(DF),and then the optimized laser decontamination parameters were obtained.Using the optimized parameters,the laser decontamination was studied with the simulated stainless steel specimens by the laser decontamination equipment.The experimental results show that the DF is more than 200,and the peeling thickness on the stainless steel base is less than 20 μm.关键词
激光去污/放射性模拟样片/工艺参数Key words
laser decontamination/radioactive simulated specimens/processing parameters分类
能源科技引用本文复制引用
马梅花,高智星,汤秀章,郑佐西,朱欣研,张怡,刘雨昕..不锈钢放射性模拟样片在空气中的激光去污技术[J].核化学与放射化学,2017,39(1):69-71,3.