| 注册
首页|期刊导航|电力系统保护与控制|新疆强风沙尘环境下750 kV线路运维技术

新疆强风沙尘环境下750 kV线路运维技术

李娟 廖峥 张陵 熊小伏 梁乃锋 张英杰 康玉函 周二彪

电力系统保护与控制2017,Vol.45Issue(2):123-130,8.
电力系统保护与控制2017,Vol.45Issue(2):123-130,8.DOI:10.7667/PSPC160163

新疆强风沙尘环境下750 kV线路运维技术

Operation and maintenance techniques for 750 kV transmission lines under severe wind and sand-dust weather in Xinjiang

李娟 1廖峥 2张陵 1熊小伏 2梁乃锋 1张英杰 1康玉函 1周二彪1

作者信息

  • 1. 国网新疆电力公司经济技术研究院,新疆乌鲁木齐830011
  • 2. 输配电装备及系统安全与新技术国家重点实验室(重庆大学),重庆400044
  • 折叠

摘要

Abstract

To ensure the normal operations of UHV transmission lines under strong wind and sand-dust conditions and the safety of transmission line and power grid,the prevention measures to encroachments by strong wind and sand-dust are presented in allusion to the 750 kV UHV transmission lines.Through summarizing the meteorological characteristics of Xinjiang region and analyzing the fault events that may occur in transmission lines of Xinjiang power grid under the effect of strong wind and sand-dust conditions,including the particular technical methods to prevent from shed skirt fracture of insulator,wear and tear of metal fittings and jumper conductors of UHV transmission lines,etc.Combining with some actual fault cases and the corresponding fault disposal measures of 750 kV transmission line in Xinjiang,it shows that this method is practical and effective in improving the ability of enduring strong wind and sand-dust conditions for 750 kV UHV transmission lines,and can be used in future design and provide valuable reference for transmission lines operating with high reliability in strong wind and sand-dust area.

关键词

气象灾害/线路故障/运行维护/强风/沙尘

Key words

meteorological disaster/transmission line fault/operation maintenance/strong wind/sand-dust

引用本文复制引用

李娟,廖峥,张陵,熊小伏,梁乃锋,张英杰,康玉函,周二彪..新疆强风沙尘环境下750 kV线路运维技术[J].电力系统保护与控制,2017,45(2):123-130,8.

电力系统保护与控制

OA北大核心CSCDCSTPCD

1674-3415

访问量3
|
下载量0
段落导航相关论文