| 注册
首页|期刊导航|理化检验-物理分册|预拉伸样坯尺寸对应变时效敏感性试验结果的影响

预拉伸样坯尺寸对应变时效敏感性试验结果的影响

徐卫星 徐惟诚 陆海兵

理化检验-物理分册2017,Vol.53Issue(3):185-187,3.
理化检验-物理分册2017,Vol.53Issue(3):185-187,3.DOI:10.11973/lhjy-wl201703009

预拉伸样坯尺寸对应变时效敏感性试验结果的影响

Effect of the Pre-stretch Specimen Dimension on the Results ofStrain Aging Sensitivity Test

徐卫星 1徐惟诚 1陆海兵1

作者信息

  • 1. 上海宝钢工业技术服务有限公司 检化验事业部, 上海 200941
  • 折叠

摘要

Abstract

The pre-stretch specimens, whose dimension conformed to the requirement of GB/T 4160-2004, were easy to neck or break at the clamping section before the pre-stretch strain reached the stipulated strain, and the tests failed.In order to avoid the above situation, the tensile tests with 5% and 10% straining and Charpy impact tests at a series of temperatures were carried out on the specimens whose shape and cross-section dimension were different from those of the standard specimens.The results show that: the dimension of pre-stretch specimens had no significant effect on the results of strain aging sensitivity test;different cross sectional dimensions of pre-stretch specimens could be acceptable during the strain aging sensitivity test of steel materials, such as rectangular specimens with grip ends of the tension test at ambient temperature.

关键词

应变时效敏感性/样坯尺寸/预拉伸/夏比冲击

Key words

strain aging sensibility/specimen dimension/pre-stretch/Charpy impact

分类

矿业与冶金

引用本文复制引用

徐卫星,徐惟诚,陆海兵..预拉伸样坯尺寸对应变时效敏感性试验结果的影响[J].理化检验-物理分册,2017,53(3):185-187,3.

理化检验-物理分册

1001-4012

访问量0
|
下载量0