热力发电2017,Vol.46Issue(2):94-99,6.DOI:10.3969/j.issn.1002-3364.2017.02.094
300MW机组富氧煤粉锅炉燃烧和烟气系统动态特性仿真分析
Numerical simulation on dynamic performance of combustion and flue gas system in a 300 MW oxy-coal fired boiler
高建强 1张晨1
作者信息
- 1. 华北电力大学能源动力与机械工程学院,河北保定071003
- 折叠
摘要
Abstract
Taking a 300 MW oxy-coal fired boiler unit as the research object,the integrated modular modeling system (IMMS) was applied to establish the dynamic simulation model for the whole unit.Under the BMCR condition,the effects of coal feeder speed and primary recirculation fan damper opening degree on the combustion and flue gas systems of the boiler were analyzed.The results show that,the coal feeder speed disturbance has great direct influence on flue gas flow and heat transfer in the combustion and flue gas system,it also has a certain effect on the parameters of the flue gas and steam.Factors such as the primary recirculation fan damper opening disturbance,the secondary recirculation fan speed disturbance and the compressor speed disturbance mainly affect the flue gas flow,and then affect the heat transfer of the unit,while they have relatively weak influence on the steam parameters.关键词
富氧燃烧/煤粉锅炉/扰动试验/烟气系统/动态特性/仿真模型Key words
oxy-coal firing/coal-fired boiler/disturbance test/flue gas system/dynamic characteristics/simulation model分类
能源科技引用本文复制引用
高建强,张晨..300MW机组富氧煤粉锅炉燃烧和烟气系统动态特性仿真分析[J].热力发电,2017,46(2):94-99,6.