| 注册
首页|期刊导航|热力发电|非对称高速贴壁风系统在530 MW俄制机组上的应用

非对称高速贴壁风系统在530 MW俄制机组上的应用

梁学斌 孙军 蒙毅 杜智华 张建辉 刘应文

热力发电2017,Vol.46Issue(3):87-92,6.
热力发电2017,Vol.46Issue(3):87-92,6.DOI:10.3969/j.issn.1002-3364.2017.03.087

非对称高速贴壁风系统在530 MW俄制机组上的应用

Application of non-symmetrical high-speed closing-to-wall air system to a Russian-made 530 MW unit coal fired boiler

梁学斌 1孙军 2蒙毅 2杜智华 2张建辉 1刘应文1

作者信息

  • 1. 天津国华盘山发电有限责任公司,天津蓟县301900
  • 2. 西安热工研究院有限公司,陕西西安710032
  • 折叠

摘要

Abstract

To prevent high temperature corrosion of water walls in boiler furnace and reduce NOx emission from a Russian-made 530 MW unit coal fired boiler,the non-symmetrical high speed closing-to-wall air system was designed and applied.Moreover,the corresponding combustion adjusting tests were carried out.The results show that,after the technical transformation and the combustion adjusting tests,the atmosphere close to the water wall was improved obviously,the high temperature corrosion on the water wall was dramatically prevented,the NOx concentration at the SCR reactor inlet can be kept between 150 mg/m3 and 170 mg/m3,and the boiler efficiency can be increased by 0.2%.The operating security,economy and environmental protection performance of the boiler improved obviously.The results have a demonstration function for NOx emission control and prevention of high temperature corrosion on water walls of the wall type opposed firing boilers.

关键词

燃煤锅炉/俄制机组/非对称高速贴壁风系统/对冲燃烧/高温腐蚀/NOx排放/热效率

Key words

coal-fired boiler/Russian-made unit/non-symmetrical high-speed closing-to-wall air system/opposed firing/high-temperature corrosion/NOx emission/thermal efficiency

分类

能源科技

引用本文复制引用

梁学斌,孙军,蒙毅,杜智华,张建辉,刘应文..非对称高速贴壁风系统在530 MW俄制机组上的应用[J].热力发电,2017,46(3):87-92,6.

热力发电

OA北大核心CSTPCD

1002-3364

访问量0
|
下载量0
段落导航相关论文