摘要

Abstract

In order to realize the traceable trans-scale displacement measurements with high resolutions in the fields of funda-mental scientific research and ultra-precision machining, we demonstrate a trans-scale heterodyne interferometer with a sub-nanometer resolution, through assembling a compact iodine-stabilized laser at 532 nm. Using modulation transfer spectroscopy, the green laser is traced back to the transition line R(56)32-O(a10), which is one of the recommended spectral lines for 'meter' redefinition. The Allan standard deviation of the laser frequency is 1.3 × 10?12 within an average time of 1 s. Compared with most He-Ne lasers, the green laser has a short wavelength and good stability, which leads to a higher resolution. We use two acoustic-optic modulators driven by a two-channel acoustic-optic driver sharing the same crystal oscillator to separate input beams spatially. The frequency of one beam is shifted by 80 MHz and the other is shifted by 82 MHz, which results in a beat frequency of 2 MHz. As a result, the nonlinearity caused by source mixing substantially is reduced. The phase noises of the fibers and two acoustic-optic modulators are well compensated. In order to minimize the difficulty in adjusting the optical path and the error of the measurement, we integrate the inter-ferometry components and design a monolithic prism. The optical resolution of the interferometer reaches to λ/4. The experiment is carried out in a vacuum environment to reduce the influence of the refractive index of air. High-precision phase measurement technology is used to improve the accuracy of the interferometer. The errors of the interferometer can be classified as random and systematic errors. Random errors include the error from the frequency instability of the laser and the error due to environmental effects. Systematic errors include the phase measurement error and the nonlinearity error. To verify the performance of the interferometer, these errors must be evaluated. In a span of 100 mm, the measurement uncertainties caused by laser wavelength uncertainty, the air refractive index uncertainty, the phase measurement uncertainty and the nonlinearity error are 3 pm, 300 pm, 6.3 pm and 118 pm, respectively. Finally, the performance evaluation shows that the combined uncertainty of the interferometer reaches 322 pm in a span of 100 mm, which is mainly due to the refractive index of air. The heterodyne interferometer meets the requirements for traceable trans-scale measurement with a sub-nanometer resolution, which can be widely used in instrument calibration, length standard making, and geometric measurement.

关键词

跨尺度/可溯源/测量/干涉仪

Key words

trans-scale/traceable/measurement/interferometer

引用本文复制引用

贺寅竹,赵世杰,尉昊赟,李岩..跨尺度亚纳米分辨的可溯源外差干涉仪[J].物理学报,2017,66(6):43-50,8.

基金项目

国家自然科学基金(批准号:51575311)和国家重大科学仪器设备开发专项(批准号:2014YQ09070907)资助的课题. Project supported by the National Natural Science Foundation of China (Grant No. 51575311) and the National Key Scientific Instrument and Equipment Development Project of China (Grant No. 2014YQ09070907). (批准号:51575311)

物理学报

OA北大核心CSCDCSTPCDSCI

1000-3290

访问量1
|
下载量0
段落导航相关论文