In order to evaluate the uncertainty of determination of Cr content in cabbage samples by graphite furnace atomic absorption spectrometry,according to the JJF 1059-1999 Chinese Regulation on the Valuation and Expression of Uncertainty in Measurement,the sources of uncertainty in determination of Cr content in cabbage samples are analyzed.Furthermore,the combined uncertainties and expanded uncertainties are calculated based on the established mathematic models of evaluation uncertainty.The result shows that the Cr content in cabbage samples in this study is (1.50±0.24) mg/kg (k=2),and the main sources of uncertainty in the determination are as follows:repeatability of measurement,Cr content in cabbage samples,the quality of the samples,Cr content in reagent blank and the constant volume.This method accurately reflects the confidence and accuracy of the measurement,and provides reference for the daily actual inspection work.关键词
化学分析/原子吸收光谱法/石墨炉/圆白菜/铬含量/不确定度Key words
chemical analysis/atomic absorption spectrometry/graphite furnace/cabbage/chromium content/uncertainty分类