流体机械2017,Vol.45Issue(3):75-80,6.DOI:10.3969/j.issn.1005-0329.2017.03.016
地下工程调温除湿机的节能优化方案及性能模拟研究
Study on Energy Saving Optimization Scheme and Performance Simulation of Dehumidifierwith Temperature Controlin Underground Engineering
魏睆 1缪小平 1张翼 1魏子杰 1羊雷 2邵光明1
作者信息
- 1. 解放军理工大学,江苏南京 210007
- 2. 东部战区陆军工程科研设计所,江苏南京 210016
- 折叠
摘要
Abstract
Based on the conversion principle of heat entranspy and moisture entranspy,the performance of current dehumidifier with temperature control was analyzed,energy saving optimization scheme was proposed.This scheme added a cooling coil before the evaporator in dehumidifier with temperature control.It is possible to precool moist air before dehumidifying along the line close to saturation and achieve the goal of energy saving.Through the simulation result of dehumidifier with temperature control system,we got a useful temperature range of cooling water in cooling coil is 18~25℃ and tempering temperature range is 15~37.5℃ in system model of dehumidifier with temperature control.关键词
地下工程/调温除湿机/分析/节能/模拟Key words
underground engineering/dehumidifier with temperature control/entranspy analysis/energy saving/simulation分类
机械制造引用本文复制引用
魏睆,缪小平,张翼,魏子杰,羊雷,邵光明..地下工程调温除湿机的节能优化方案及性能模拟研究[J].流体机械,2017,45(3):75-80,6.